REMOVE RH LOWER MOTOR MOUNT BRACKET
This tutorial shows how to remove the RH Lower Motor Mount Bracket from the XE-1
1. Work Instruction - Remove RH Lower Motor Mount Bracket
TOOLS REQUIRED
ID | Description | Task |
M5 Hex Key |
Loosen M6 Cap Screws |
|
10 MM Open/Combination Wrench |
Loosen M6 Nylock Nut |
1.1 Remove the M6 x 25 mm Cap Screw with M6 Washer from the RH Lower Motor Mount Bracket.
1.2 Remove the M6 Stainless Steel Nylock Nut, Stainless Steel Washer and short Nylon Sleeve (bush with shoulder), from the 70 mm length M6 Stainless Steel Cap Screw.
1.3 Remove the RH Lower Motor Mount Bracket.
1.4 Remove the Motor Mount Spacer.